The microprocessor-controlled, Roof-Mounted Air Conditioning Packaging Unit (RMPU) serves to maintain passenger comfort within the coaches by regulating temperature and humidity levels. Based on ambient temperature conditions, the operational modes of heating, ventilation, cooling, and dehumidification can be selected via the Human-Machine Interface (HMI) panel. Microprocessor controlled, Roof mounted Cab AC Unit maintains comfort for the driver inside the cab by controlling the temperature and humidity level. Depending on ambient temperature, the unit can be operated in Auto and Manual mode.
Salient Features
- • Cooling capacity > 8 T.R. (or) 28.1 kW
- • Heating capacity ~10 kW
- • Maximum power consumption : 18.5 kVA
- • Robust and lightweight housing structure made of SS-304 grade S2 material
- • Servo-motor controlled fresh air flow for automatic pre-cooling/pre-heating
- • Operating Conditions: -10°C to +60°C
- • Cooling Capacity: 2 TR @ 35°C ambient, 1.5 TR @ 50°C ambient
- • Heating Capacity: 2 kW
- • Controlling System: Solid State Temperature Controller
- • Operating Modes: 3-Position Mode Switch (OFF, AUTO, MANUAL)
- • Air Flow @ Centrifugal Fan: 1200 CMH
- • Intelligent micro controller - as per RDSO specs (RDSO /PE/ SPEC / EMU / 0196-2019 (Rev.O) RS-485) port for TCMS connectivity in future
- • Complies with UIC 553, IC 61373, IC 60571
-
• Temperature Set Point (°C)
- • Cooling: 23°C to 25°C
- • Heating: 19°C to 21°C
MRVC 2TR Tower AC
Electrical Requirement:
- • Power Supply - 3 Phase, 415 V 50 Hz
- • Power Consumption - 4.5 KW MAX.
Capacity:
- • Cooling Capacity 7 KW. / 2 Tr.
- • Heating Capacity 1 KW.
Constructional Requirement:
- • Design to Ambient (Cooling) 50°C
- • Max Operating Temperature 57°C
- • Material for Housing - SS 304 grade S2.
- • Refrigerant - R-407C
- • Weight - 210 KG MAX.
- • Relative Humidity - Up to 100%.